| Low Expansion Foam Branch Pipes |
|
 |
| Model B |
 |
Inlet Connection |
: 2 ½" Instantaneous |
 |
Material |
: Aluminum Alloy Or Stainless Steel |
 |
Working Pressure |
: 145 PSI Max. |
 |
Foam Expansion |
: 8 to 10 times |
 |
Foam Induction |
: Available with foam inductor |
|
|
| |
| Description |
Flow @ 100 PSI |
Throw Range in Meters |
| In Aluminium Alloy Construction |
60 GPM |
18 |
| In Brass Construction |
60 GPM |
18 |
|
| |
| |
| Medium Expansion Foam Branch-Pipe |
|
 |
 |
Inlet Connection |
: 2 ½" Instantaneous as per BS 336 |
 |
Material |
: Stainless Steel |
 |
Working Pressure |
: 10 bar Max. |
 |
Foam Expansion |
: 50 times |
|
|
| |
| Description |
Flow @ 100 PSI |
Throw Range in Meters |
| With inbuilt foam inductor |
60 GPM |
6 to 8 |
| Without inbuilt foam inductor |
120 GPM |
9 to 11 |
|
| |
| |
|
 |
| Foam Maker with Vapour Seal |
 |
Applicable for fixed roof tank |
 |
Available in wide flow range |
 |
Treated with anti corrosive treatment |
 |
Suitable for all types of foam concentrate |
 |
3 to 4 % Foam Expansion |
 |
Flange connections as per ANSI |
|
|
| |
| Inlet Connection (NB) |
Outlet Connection (NB) |
Flow @ 50
PSI |
Flow @ 50
PSI |
| 2” |
3” |
20 to 60 GPM |
Mild steel
|
| 2
½” |
4” |
60 to 120 GPM |
| 3” |
6” |
120 to 240 GPM |
| 4” |
8” |
240 to 475 GPM |
| 6” |
10” |
475 to 715
GPM |
|
| |
| |
|
 |
| Foam Maker with Vapour Seal |
 |
Applicable for fixed roof tank |
 |
Available in wide flow range |
 |
Treated with anti corrosive treatment |
 |
Suitable for all types of foam concentrate |
 |
3 to 4 % Foam Expansion |
 |
Flange connections as per ANSI |
|
|
| |
| Inlet Connection (NB) |
Outlet Connection (NB) |
Flow @ 50
PSI |
Flow @ 50
PSI |
| 2” |
3” |
20 to 60 GPM |
Mild steel
|
| 2
½” |
4” |
60 to 120 GPM |
| 3” |
6” |
120 to 240 GPM |
| 4” |
8” |
240 to 475 GPM |
| 6” |
10” |
475 to 715
GPM |
|
| |
| |
|
 |
| Miniturbex |
 |
Compact, Light weight |
 |
Portable Can carry by single person |
 |
Corrosion proof construction |
 |
Can be used as a smoke extractor |
 |
Foam Induction 3% |
 |
Suitable for all types of foam concentrate |
 |
Supplied with suitable foam inductor |
 |
Nylon Net foam ducting and Smoke ducting - Std Accessories |
|
|
It is high expansion Foam Generator .It unit is consisting of stainless steel casing; a pelton wheel turbine drives a fan, four jets nozzles to discharge water foam solution in front of high velocity air. Foam making net used for making foam. A inline inductor is used for inducting foam.
|
| |
Inlet
Connection (NB) |
Flow @
50 PSI |
Foam Produced |
Smoke Extracted |
2
½”male Instantaneous
As per Bs336 |
65 GPM |
2825 Ft3/ min |
3460
Ft3/min |
|
| |
| |
|
 |
| HI-EX |
 |
Having by pass valve to control foam production |
 |
Can be used as a smoke extractor |
 |
Lightweight |
 |
Portable |
 |
Corrosion proof body made of FRP |
 |
Low maintenance |
 |
2½" Male instantaneous connection. |
 |
Inbuilt foam Inductor. |
 |
Nylon net.foam ducting and smoke ducting Std. accessories. |
|
|
It is high expansion Foam Generator. It consists of a fan driven by directly the shaft of water turbine, which blows air to nylon net. The net is wetted by foam water solution from spray nozzle .The foam concentrate being drawn into the water stream by means of a built in Induction System.
|
| |
Operating
Condition |
Inlet
Pressure |
Total water Flow (GPM) |
By Pass
Flown (GPM) |
Expanded Foam
(M3/min) |
Expansion |
By-Pass Valve Closed
|
7 bar |
61 |
38 |
145 |
800 to 1100 |
| By-Pass Valve Open |
7 bar |
58 |
nil |
132 |
500 to 750 |
|
| |
| |
|
 |
| Inline Foam Generator |
 |
Inline foam generator is modified version of Inline inductor. It inducts foam as well as expands it and also transports the foam a long distance |
 |
Inlet Connection |
2½" Male Instantaneous |
 |
Outlet Connection |
2½" Female Instantaneous |
 |
Foam Induction |
3 to 6% |
 |
Max. Working Pressure |
145 PSI |
 |
Construction |
Aluminium Alloy Or Gun Metal |
|
|
|
| It is high expansion Foam Generator. It consists of a fan driven by directly the shaft of water turbine, which blows air to nylon net. The net is wetted by foam water solution from spray nozzle .The foam concentrate being drawn into the water stream by means of a built in Induction System. |
| |
| Description |
Material of
Construction |
| 60 GPM @100 PSI |
Aluminium Alloy
Gun
Metal |
| 120 GPM @100
PSI |
|
| |
| |
|
 |
| In FRP tank |
 |
Made with corrosion resistance FRP tank |
 |
Light weight ,aerodynamically shaped |
 |
Unit equipped with foam inductor, low expansion branch pipe,
Fire Hoses |
 |
Suitable for all type of foam concentrates |
 |
Low Maintenance |
|
|
| |
| Tank Capacity |
| 100 liters |
| 150 liters |
| 200 liters |
|
| |
| |
|
 |
| In Steel |
 |
Stainless Steel tank |
 |
Slim line ,Compact design |
 |
Low center of gravity, make steering easier |
 |
Unit equipped with foam inductor, low expansion branch pipe , Fire Hoses |
 |
Suitable for all type of foam concentrates |
 |
Low Maintenance |
|
|
| |
| Tank Capacity |
| 100 liters |
| 150 liters |
| 200 liters |
|
| |
| |
|
 |
| Variable Inline Indicator |
 |
Inlet and outlet connections |
 |
Foam induction rates can be adjusted from 0% to 6% |
 |
Body material : Aluminium |
 |
Inbuilt non return valve to foam inlet |
 |
Foam concentrate drawn through a Pick up tube |
 |
Light weight, portable |
|
|
| |
| Tank Capacity |
| 60 GPM |
| 120 GPM liters |
|
| |
| |
|
 |
| Fixed Inline Indicator |
 |
For fixed installation systems |
 |
With 3 to 6% foam induction |
 |
Available in wide range of flow |
 |
Carbon steel construction treated with anti corrosive coatings |
 |
Flanged inlet & outlet connection as per ANSI |
|
|
| |
| Inlet & outlet Flanges NB |
Flow rate @100 PSI |
End Connection |
| 2” |
20-60 GPM |
Instantaneous As Per BS 336
Flanged As Per ANSI |
| 2.5” |
60-120 GPM |
| 3” |
120-240 GPM |
Flanged As Per ANSI |
| 4” |
240-480 GPM |
| 6” |
480-715 GPM |
| 8” |
715-950 GPM |
|
| |
| |
| Foam Used in Fire Protection |
|
 |
| Protein Foam Compound |
 |
DIFR Tested & TAC Approved |
 |
Synthetic polyvalent foam forming liquid, psuedo-plastic consisting of surface active substances and polymer additives. |
 |
Having good resistance to contamination of hydrocarbons and to dehydration of polar solvents. |
 |
It is to be used in 3% concentration on hydrocarbons and at 6% concentration on polar solvents. |
|
|
| |
| Description |
Packing Available in |
| As above |
20 Ltrs Steel drums
20 /Ltrs Polyethylene Jerry cans
30 Ltrs Polyethylene Jerry cans
200 Ltrs Steel Barrels. |
|
| |
| |
| Foam Used in Fire Protection |
|
 |
| Fluoro Protein Foam Compound |
 |
Conforms to IS: 4989-Part-3, ISI marked, TAC Approved DIFR Tested |
 |
It is specially formulated by combining selected fluorotensides with a protein base |
 |
To obtain optimum foaming it is recommended that an induction of foam compoun is 3 to 4 % for long throw equipment and for adhesive foam, a higher rate of 5-6 % foam induction is recommended. |
 |
Depending on type of equipment, water pressure and induction, the expansion rate varies between 6-10 |
|
|
| |
| Description |
Packing Available in |
| As above |
20 Ltrs Steel drums
20 /Ltrs Polyethylene Jerry cans
30 Ltrs Polyethylene Jerry cans
200 Ltrs Steel Barrels. |
|
| |
| |
| Foam Used in Fire Protection |
|
 |
| High Expansion Foam Compound |
 |
HIEX Foam Controls Class A fires by oxygen exclusion and limiting heat radiation |
 |
Effective smoke and heat barriers are quickly created permitting other fire fighting equipment to tackle the seat of the fire |
 |
Class B fire fighting is efficient since HIEX foam very quickly covers flammable liquid surface without splashing and helps to cut off flammable vapor releases |
 |
Conforms to Home Office ( UK ) Specification JCDD : 28 |
 |
DIFR Tested & Approved |
 |
Excellent with all fire extinguishing chemicals |
|
|
| |
| Description |
Packing Available in |
| As above |
20 Ltrs Steel drums
20 /Ltrs Polyethylene Jerry cans
30 Ltrs Polyethylene Jerry cans
200 Ltrs Steel Barrels. |
|
| |
| |
| Foam Used in Fire Protection |
|
 |
| Aqueous Film Foam (AFFF) |
 |
UL listed |
 |
ISI Marked, as per IS : 4989-PART-II DIFR Tested, TAC Approved |
 |
AFFF is a synthetic based foam compound mixed with addition of fluorotensidepossessing the property to create the film of water solution that floats on top of non-polar flammable liquids |
|
|
| |
| Description |
Packing Available in |
| Non UL listed |
20 Ltrs Polythylene Jerry cans
30 Ltrs Polythylene Jerry cans
200 Ltrs Polythylene Jerry cans |
| UL listed |
|
| |
| |
|
 |
 |
Complete With DCP Containers, Nitrogen Cylinder, & Valve Assembly |
 |
Agent Capacity of 150 to 3000 Pounds or 68 to 1360 Kg. |
 |
Can Be used as a compact stationary fire extinguisher, used with Hose reel or used with fixed installation DCP System |
 |
Optional Hose reel , Selector Valves , Skid Mounting, trailer Mounting . |
|
|
| |